            Your present location:home >> Products >> Bare Overhead Conductor >> AAAC with ASTM B399 Standard >> AAAC conductor with ASTM B399 standard

            PRODUCTS

            • Name: AAAC conductor with ASTM B399 standard
            • Views : 301

                Application

              Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives AAAC higher resistance to corrosion than ACSR.

                Standard

              AAAC bare conductor meets or exceeds the following ASTM specifications:

              B-398 Aluminum Alloy 6201-T81 Wire for Electrical Purposes

              B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors

                   Note: this AAAC bare overhead conducotr also can be manufactured according to your special request.

                Construction

              Standard 6201-T81 high strength aluminum conductors, conforming to ASTM Specification B-399, are concentric-lay-stranded, similar in construction and appearance to 1350 grade aluminum conductors. Standard 6210 alloy conductors are similar to other alloy conductors commercially known as Ardival, Aldrey or Almelec. They were developed to fill the need for an economical conductor for overhead applications requiring higher strength than that obtainable with 1350 grade aluminum conductors, but without a steel core. The DC resistance at 20 °C of the 6201-T81 conductors and of the standard ACSR of the same diameter are approximately the same. Conductors of the 6201-T81 alloys are harder and , therefore, have a greater resistance to abrasion than conductors of 1350-H19 grade aluminum.

                Brief Specification

            Code Name
            Area
            Size & Stranding of ACSR with Equal Diameter
            No. & Diameter of wires
            Overall Diameter
            Weight
            Nominal Breaking Load
            Area
            Stranding and Wire Diameter
             
            Approx Overall Diameter
            Weight
            Nominal Breaking Load
            Max.D.C. Resistance at 20℃
            Nominal
            Actual
            Nominal
            Actual
            MCM
            mm2
            AWG or MCM
            Al/Steel
            mm
            mm
            kg/km
            kN
            AWG or MCM
             mm²
            mm
            mm
            kg/km
            kN
            Ω/km
            Akron
            30.58
            15.48
            6
            6/1
            7/1.68
            5.04
            42.7
            4.92
            6
            13.3
             7/1.554
            4.67
            37
            4.22
            2.5199
            Alton
            48.69
            24.71
            4
            6/1
            7/2.12
            6.35
            68.0
            7.84
            4
            21.15
             7/1.961
            5.89
            58
            6.71
            1.5824
            Ames
            77.47
            39.22
            2
            6/1
            7/2.67
            8.02
            108
            12.45
            2
            33.63
             7/2.474
            7.42
            93
            10.68
            0.9942
            Azusa
            123.3
            62.38
            1/0
            6/1
            7/3.37
            10.11
            172
            18.97
            1/0
            53.48
             7/3.119
            9.36
            148
            16.97
            0.6256
            Anaheim
            155.4
            78.65
            2/0
            6/1
            7/3.78
            11.35
            217
            23.93
            2/0
            67.42
             7/3.503
            10.51
            186
            20.52
            0.4959
            Amherst
            195.7
            99.22
            3/0
            6/1
            7/4.25
            12.75
            273
            30.18
            3/0
            85.03
             7/3.932
            11.8
            234
            25.86
            0.3936
            Alliance
            246.9
            125.1
            4/0
            6/1
            7/4.77
            14.31
            345
            38.05
            4/0
            107.23
             7/4.417
            13.26
            296
            32.63
            0.3119
            Butte
            312.8
            158.6
            266.8
            26/7
            19/3.26
            16.30
            437
            48.76
            250
            126.66
            19/2.913
            14.57
            349
            38.93
            0.2642
            Canton
            394.5
            199.9
            336.4
            26/7
            19/3.66
            18.30
            551
            58.91
            300
            152.1
            19/3.193
            15.97
            419
            46.77
            0.2199
            Cairo
            465.4
            235.8
            397.5
            26/7
            19/3.98
            19.88
            650
            69.48
            350
            177.35
            19/3.447
            17.24
            489
            52.25
            0.1887
            Darien
            559.5
            283.5
            477.0
            26/7
            19/4.36
            21.79
            781
            83.52
            400
            202.71
            19/3.686
            18.43
            559
            59.74
            0.165
            Elgin
            652.4
            330.6
            556.5
            26/7
            19/4.71
            23.54
            911
            97.42
            450
            228
            19/3.909
            19.55
            629
            67.19
            0.1467
            Flint
            740.8
            375.3
            636.0
            26/7
            37/3.59
            25.16
            1035
            108.21
            500
            253.35
            19/4.120
            20.6
            698
            74.64
            0.1321
            Greely
            927.2
            469.8
            795.0
            26/7
            37/4.02
            28.14
            1295
            135.47
            550
            278.6
            37/3.096
            21.67
            768
            83.8
            0.1202
                             
            600
            303.8
            37/3.233
            22.63
            838
            91.38
            0.1102
                             
            650
            329.25
            37/3.366
            23.56
            908
            97.94
            0.1016
                             
            700
            354.55
            37/3.493
            24.45
            978
            102.2
            0.0944
                             
            750
            380.2
            37/3.617
            25.32
            1049
            109.6
            0.088
                             
            800
            405.15
            37/3.734
            26.14
            1117
            116.8
            0.0826
                             
            900
            456.16
            37/3.962
            27.73
            1258
            131.5
            0.0733
                             
            1000
            506.71
            37/4.176
            29.23
            1399
            146.1
            0.066

              Note:

               1. Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 52.5% IACS, AC resistance at 60Hz

               2. Current ratings are based on 75°C conductor temperature, 25°ambient,2ft/s wind, 96/watts/sq.foot sun,.05 coefficients of emissivity and absorption.

             

               For more information about AAAC conductor, please contact us freely. Your message will be applied in first time!

            Message Chat Now

             
            Inquiry:
            * Entered characters:0 Word
            Less than or equal500Character
            Name:
            *
            In less than 20 characters (including A-Z, a-z, 0-9, Chinese characters, excluding special characters)
            Email:
            *
            Example:example@mail.com